Phase fluctuation compensation for long-term transfer of stable radio frequency over fiber link

Bo Ning1, Peng Du, Dong Hou

  • 1Department of Electronics, Peking University, Beijing 100871, China.

Optics Express
|December 25, 2012
PubMed

Related Concept Videos

Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
Properties of Fourier Transform II01:24

Properties of Fourier Transform II

The Fourier Transform (FT) is an essential mathematical tool in signal processing, transforming a time-domain signal into its frequency-domain representation. This transformation elucidates the relationship between time and frequency domains through several properties, each revealing unique aspects of signal behavior.
The Frequency Shifting property of Fourier Transforms highlights that a shift in the frequency domain corresponds to a phase shift in the time domain. Mathematically, if x(t) has...
Properties of Fourier Transform I01:21

Properties of Fourier Transform I

The application of Fourier Transform properties in radio broadcasting is multifaceted, enabling significant advancements in the way signals are transmitted and received. Key areas where these properties are utilized include simultaneous multi-channel transmission, audio clip speed adjustments, live broadcast delays for different time zones, audio frequency adjustments, and signal demodulation.
In radio broadcasting, multiple audio signals often need to be transmitted simultaneously. The Fourier...