Abstract:
Hemodynamic monitoring is essential to the care of the critically ill patient. In the hemodynamically unstable patient where volume status is not only difficult to determine, but excess fluid administration can lead to adverse consequences, utilizing markers that guide resuscitation can greatly affect outcomes. Several markers and devices have been developed to aid the clinician in assessing volume status with the ultimate goal of optimizing tissue oxygenation and organ perfusion. Early static measures of volume status, including pulmonary artery occlusion pressure and central venous pressure, have largely been replaced by newer dynamic measures that rely on real-time measurements of physiological parameters to calculate volume responsiveness. Technological advances have lead to the creation of invasive and noninvasive devices that guide the physician through the resuscitative process. In this manuscript, we review the physiologic rationale behind hemodynamic monitoring, define the markers of volume status and volume responsiveness, and explore the various devices and technologies available for the bedside clinician.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Continuous Renal Replacement Therapy
Rheumatic Heart Disease IV: Nursing Management
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring