Abstract:
Experiments were conducted in a laboratory-scale biofilter to assess the ability of a fixed-film biological process to treat an air stream containing β-caryophyllene, a sesquiterpene emitted by a variety of conifer trees as well as industrial wood processing operations. Treatment performance was evaluated under a variety of pollutant loading conditions and nutrient supply rates over an operational period lasting more than 240 days. At empty bed contact times (EBCTs) as low as 10 s and daily average pollutant loading rate as high as 24.2 g C/(m(3) h) (grams pollutant measured as carbon per cubic meter packed bed volume per hour), removal efficiencies in excess of 95 % were observed when sufficient nutrients were supplied. Results demonstrate that, as with biofilters treating other compounds, biofilters treating β-caryophyllene can experience local nutrient limitations that result in diminished performance. The biofilter successfully recovered high removal efficiency within a few days after resumption of pollutant loading following a 14-day interval of no contaminant loading. Construction of a 16S rRNA gene library via pyrosequencing revealed the presence of a high proportion of bacteria clustering within the genera Gordonia (39.7 % of the library) and Rhodanobacter (37.6 %). Other phylotypes detected at lower relative abundances included Pandoraea (6.2 %), unclassified Acetobacteraceae (5.5 %), Dyella (3.3 %), unclassified Xanthomonadaceae (2.6 %), Mycobacterium (1.8 %), and Nocardia (0.6 %). Collectively, results demonstrate that β-caryophyllene can be effectively removed from contaminated gas streams using biofilters.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
Related Concept Videos
Microbial Bioremediation of Hydrocarbons
Microbial Bioremediation of Pesticides
Bioremediation
Bioplastics
Environmental Applications of Microorganisms