Related Experiment Video
Updated: May 15, 2026

Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Tissue oxygen saturation changes during intramedullary nailing of lower-limb fractures
Natalie Enninghorst1, Benjamin M Hardy, Krisztian Sisak
1Department of Traumatology, Division of Surgery, John Hunter Hospital, University of Newcastle, Newcastle, New South Wales, Australia.
Background:
The systemic complications of acute intramedullary nailing (IMN) in trauma patients are well known. There are no reliable methods available to predict these adverse outcomes. Noninvasive near-infrared spectroscopy (NIRS) allows measurement of oxygen saturation within muscle tissue (StO2) and quantification of the potential metabolic and microcirculatory effects of IMN in real time. The aim of this study was to characterize tissue oxygenation changes occurring during reamed IMN.
Methods:
Patients undergoing reamed IMN for fixation of a tibia or femur fracture and patients having an open reduction and internal fixation of the ankle (to control for potential effects of anesthesia) had a noninvasive NIRS probe attached to the thenar eminence of the hand. Tissue oxygenation was monitored continuously throughout the operation and digitally recorded for later analysis. Vascular occlusion tests, an established technique with the NIRS device, were performed before canal opening and after nail insertion (at equivalent times in the control group), to establish the presence and nature of changes in systemic microcirculation occurring during the duration of the operation.
Results:
Tissue oxygenation data were collected on 23 patients undergoing 26 IMN. (mean [SD] age, 36 [19] years; median Injury Severity Score [ISS], 9; interquartile range, 9-12). The control group consisted of 19 patients (mean [SD] age, 41 [18] years; ISS, 4). Remote muscle tissue desaturated significantly faster after IMN compared with the control operation (mean [SD] difference in IMN desaturation rate, 1.8% per minute [2.6% per minute]; mean [SD] difference in control group desaturation rate, -0.6% per minute [1.5% per minute]; p = 0.014). Near infrared-derived muscle oxygen consumption (NIR VO(2)) was significantly increased during the course of IMN compared with the control (mean [SD] difference in IMN NIR VO(2), 19.9 [32.1]; mean [SD] difference in control NIR VO(2), -4.2 [17.9]; p = 0.041).
Conclusion:
IMN causes significant remote microcirculatory changes. The responsiveness of the microcirculation could be a predictor of secondary organ dysfunction.
Level Of Evidence:
Epidemiologic study, level III.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Peripheral Artery Disease V: Postoperative Nursing Management

