Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Effect of depressed left ventricular function on hemodynamics of normal St. Jude Medical prosthesis in the aortic
J F Ren1, K Chandrasekaran, G S Mintz
1Likoff Cardiovascular Institute, Hahnemann University, Philadelphia, Pennsylvania.
Abstract:
To evaluate the effect of left ventricular (LV) dysfunction on Doppler-derived transprosthetic hemodynamic indexes in patients with normally functioning St. Jude aortic valve prostheses, 74 consecutive patients were studied. LV ejection fraction was assessed by using Simpson's biplane rule. The 34 patients with normal ejection fraction (greater than or equal to 0.51) (group A) generally had the highest values of peak (31 +/- 13 mm Hg) and mean (16 +/- 6 mm Hg) gradients, whereas 19 patients with moderate to severe reduction of ejection fraction (less than or equal to 0.31) (group C) had the lowest values (17 +/- 6 and 9 +/- 3 mm Hg, respectively) (p less than 0.05). Significant decreases (p less than 0.05) for acceleration and corrected (for heart rate) velocity time integral in group C were noted compared to group A, and group B (21 patients with mild to moderately reduced ejection fraction [0.50 to 0.32]). A significant inverse correlation for Doppler-derived peak and mean gradients and corrected velocity time integral was demonstrated with increasing aortic valve prosthetic sizes from 19 to 29 mm in group A patients (r = -0.41 to -0.71) but less so in group B or C. Thus, in addition to valve size, LV function should be considered an important factor in detecting prosthetic valvular flow characteristics and dysfunction. A normal derived velocity and gradient in patients with moderately to severely depressed LV function may not rule out significant valvular stenosis.
More Related Videos
06:56An Ex Vivo Porcine Model for Hydrodynamic Testing of Experimental Aortic Valve Procedures and Novel Medical Devices
Published on: August 25, 2023
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Mitral Stenosis I: Introduction
Mitral Stenosis III: Medical Management
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management