Related Experiment Video
Updated: May 15, 2026

Memorization-Based Training and Testing Paradigm for Robust Vocal Identity Recognition in Expressive Speech Using Event-Related Potentials Analysis
Published on: August 9, 2024
Reliability of objective voice measures of normal speaking voices
Karen Leong1, Mary J Hawkshaw, Dimiter Dentchev
1Department of Surgery, Brown University, Providence, Rhode Island, USA.
Objective:
To determine the reliability of objective voice measures used commonly in clinical practice.
Subjects:
Eighteen healthy volunteers (nine males and nine females).
Methods:
Objective voice measures were performed on 18 healthy volunteers on 10 occasions under similar conditions over a 30-day period. Consistency of measures was analyzed to determine reliability.
Results:
Using currently accepted normative values, intraclass correlation coefficients were moderate (>0.6) for consistency over the 10 testing sessions for most acoustic measures that do not depend on intensity, measures of laryngeal efficiency, and perturbation measures of fundamental frequency (F0) for both genders. For females, cepstral peak prominence (CPP) had moderate reliability, whereas for males, the smoothed CPP was reliable. Other than F0, none of the perturbation measures are reliable for females. However, jitter, relative average perturbation, and standard deviation of F0 are reliable for males. Noise-to-harmonic ratios (NHRs) had the lowest consistency of all measures over the course of the 10 sessions.
Conclusions:
Clinicians should be cautious in their use of acoustic voice measures that depend on the intensity and in their use of most perturbation measures. NHR was found to be the least reliable measure. Additionally, the reliability of CPP measure varies by gender. Understanding the degree of within-person variability on some objective voice measures and whether that variation is due to biological differences or measurement error will lead clinicians to consider the need for a more standardized testing protocol. Additional research is needed to investigate what factors within the testing protocol and/or changes to the measurement instruments may lead to more consistent test results.
More Related Videos
Related Concept Videos
Reliability and Validity
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: