Related Experiment Video
Updated: May 15, 2026

The Adjuvant Efficacy of Angong Niuhuang Pill in the Treatment of Viral Encephalitis: A Meta-Analysis of Randomized Controlled Trials
Published on: April 19, 2024
An analysis of adaptive design variations on the sequential parallel comparison design for clinical trials
Michael Y Mi1, Rebecca A Betensky
1Harvard-MIT Division of Health Sciences and Technology, Harvard Medical School, Harvard University, Boston, MA, USA.
Background:
Currently, a growing placebo response rate has been observed in clinical trials for antidepressant drugs, a phenomenon that has made it increasingly difficult to demonstrate efficacy. The sequential parallel comparison design (SPCD) is a clinical trial design that was proposed to address this issue. The SPCD theoretically has the potential to reduce the sample-size requirement for a clinical trial and to simultaneously enrich the study population to be less responsive to the placebo.
Purpose:
Because the basic SPCD already reduces the placebo response by removing placebo responders between the first and second phases of a trial, the purpose of this study was to examine whether we can further improve the efficiency of the basic SPCD and whether we can do so when the projected underlying drug and placebo response rates differ considerably from the actual ones.
Methods:
Three adaptive designs that used interim analyses to readjust the length of study duration for individual patients were tested to reduce the sample-size requirement or increase the statistical power of the SPCD. Various simulations of clinical trials using the SPCD with interim analyses were conducted to test these designs through calculations of empirical power.
Results:
From the simulations, we found that the adaptive designs can recover unnecessary resources spent in the traditional SPCD trial format with overestimated initial sample sizes and provide moderate gains in power. Under the first design, results showed up to a 25% reduction in person-days, with most power losses below 5%. In the second design, results showed up to a 8% reduction in person-days with negligible loss of power. In the third design using sample-size re-estimation, up to 25% power was recovered from underestimated sample-size scenarios.
Limitations:
Given the numerous possible test parameters that could have been chosen for the simulations, the study's results are limited to situations described by the parameters that were used and may not generalize to all possible scenarios. Furthermore, dropout of patients is not considered in this study.
Conclusions:
It is possible to make an already complex design such as the SPCD adaptive, and thus more efficient, potentially overcoming the problem of placebo response at lower cost. Ultimately, such a design may expedite the approval of future effective treatments.
More Related Videos
04:53A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
08:58Efficient Sampling of Genetically Encoded Biosensor Design Space Enabled with a Design of Experiments and Automation Workflow
Published on: October 17, 2025
Related Concept Videos
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Comparing the Survival Analysis of Two or More Groups
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview