Precordial acceleration signals improve the performance of diastolic timed vibrations
K Tavakolian1, F Khosrow-Khavar, B Kajbafzadeh
1School of Engineering Science, Simon Fraser University, British Columbia, Canada. kouhyart@sfu.ca
Background And Objective:
This paper introduces a seismocardiography based methodology of predicting the start and the end of diastole to be used in diastolic timed vibrations (DTV), which provides non-invasive emergency treatment of acute coronary thrombosis by applying direct mechanical vibrations to the patient chest during diastole of heart cycles. It is proposed that seismocardiogram (SCG), in combination with electrocardiogram (ECG), provides a new means of diastole prediction.
Methods:
An accelerometer was placed on the sternum of 120 healthy participants and 22 ischemic heart patients to record precordial accelerations created by the heart. The accelerometer signal was used to extract SCG and phonocardiogram (PCG). Two independent trained experts annotated the extracted signals based on the timings of the start and end of diastole.
Results:
In the ischemic heart disease population by using 15 consecutive SCG cycles, the start and end of diastole was predicted in the upcoming cycles with 95 percentile error margin of 10.7 ms and 5.8 ms, respectively. These error margins were 7.4 ms and 3.5 ms, respectively, for normal participants.
Conclusion:
The results provide that prediction of the aortic valve closure point in the SCG signal helps start the vibrator in time to cover most of the isovolumic relaxation period. Also, through prediction of the mitral valve closure point in the SCG signal, safety of the technique can be assessed through prediction of the amount of unwanted vibrations applied during the isovolumic contraction period.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Dysrhythmias V: Evaluating Dysrhythmias
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: