Related Experiment Video
Updated: May 15, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Evaluation of dosimetry and excess seeds in permanent brachytherapy using a modified hybrid method: a
Kana Kobayashi1, Koji Okihara, Tsuyoshi Iwata
1Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, 465 Kajiicho Kawaramachi Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan. kana-k@koto.kpu-m.ac.jp
Abstract:
Permanent prostate brachytherapy is frequently performed worldwide, and many studies have demonstrated its favorable outcomes. Implant seeds used in this procedure contain a precise amount of radionuclide and are completely sealed. Because these seeds are not manufactured in Japan, they are expensive (6300 yen per seed) and therefore need careful management as a radioisotope. The proper implantation technique requires considerable procedure time, good dosimetric outcomes and simple radioactive isotope management. To evaluate the modified hybrid interactive technique based on these considerations, we assessed 313 patients who underwent hybrid interactive brachytherapy without additional external beam radiotherapy. We evaluated the duration of the procedure, dosimetric factors and the total number of excess seeds. The dosimetric results from computed tomography on Day 30 of follow-up were: 172 Gy (range 130-194 Gy) for pD90, 97.8% (83.5-100%) for pV100, 54.6% (27.5-82.4%) for pV150, 164 Gy (120-220 Gy) for uD90, 194 Gy (126-245 Gy) for uD30, 210 Gy (156-290 Gy) for uD5, 0.02 ml (0-1.2 ml) for rV100 and 0 ml (0-0.2 ml) for rV150. The number of excess seeds was determined by subtracting the number of implanted seeds from the expected number of seeds calculated from previously proposed nomograms. As per our method, nine excess seeds were used for two patients, whereas using the nomograms, the number of excess seeds was approximately eight per patient. Our modified hybrid interactive technique reduced the number of excess seeds while maintaining treatment quality.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014