Related Experiment Video
Updated: May 15, 2026

Blind Endotracheal Intubation in Neonatal Rabbits
Published on: February 26, 2021
Leak around endotracheal tubes in ventilated newborns: an observational study
Tammy Lee Brinsmead1, Garry Donald Trevor Inglis, Robert S Ware
1Grantley Stable Neonatal Unit, Royal Brisbane & Women's Hospital, Brisbane, Queensland, Australia. tammybrinsmead@yahoo.com.au
Aim:
The study aims to determine the incidence and magnitude of leak around endotracheal tubes (ETTs) in ventilated babies in our unit, and to identify any relationship between weight, gestation, head position or ETT tip position, and the amount of leak.
Methods:
Ventilated infants in the neonatal unit of the Royal Brisbane and Women's Hospital were observed. Data were collected on ETT size, ventilator settings, body position, head position and amount of leak. Also recorded were weight, post-menstrual age and radiological position of the ETT tip.
Results:
Two hundred ninety-six sets of data were collected from 60 infants. At the time of recruitment, infants had a median (interquartile range) post-menstrual age of 32(+3) (28(+4) -36(+3)) years. Minimal leak (defined as <10% measured leak) and a small leak (10-25% leak) were observed on 162 occasions (55%) and 77 occasions (26%), respectively. A large leak of more than 25% was observed on 57 (19%) occasions. The odds of having a large leak with the head turned to the right, or midline, was greater than with the head turned to the left (odds ratio = 2.0; 95% confidence interval: 1.0 to 4.1 and 6.8; 1.4 to 31.5, respectively). Infants lying prone were more likely than those lying supine to have a leak >25% (odds ratio = 2.1; 95% confidence interval: 1.1 to 3.8). There was no association between leak and distance from carina, or weight.
Conclusions:
Few babies in our unit had a large leak around the ETT, and many had minimal leak. A leak was less likely when a baby's head was turned to the left. Further study is required to clarify the reasons for this. Weight and post-menstrual age were not associated with the extent of leak.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...