Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography (Micro-CT) Imaging Method
Published on: October 27, 2020
Normative measurements of extraocular musculature by multislice computed tomography
Zhu-Hua Zhang1, Yu Chen, Yun Wang
1Department of Radiology Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China.
Abstract:
Objective To establish the normal measurements of diameter of extraocular muscles (EOMs) by multislice computed tomography (CT). Methods Orbits of 50 volunteers (25 male and 25 female) were scanned with a multislice CT scanner. For each subject, one axial image at the central level of the eyeball, one coronal image about 1 cm behind globe, and two oblique sagittal images respectively along the left and right optic nerve were used for measurements of the thickness and width of EOMs. The statistic significance of measurement value between male and female and between left and right eyes was evaluated. Results There were no significant differences in the thickness and width of superior muscle group, lateral rectus, medial rectus, lateral rectus, superior oblique, inferior oblique and the thickness of levator palpebrae superioris between the left and right eyes as well as between male and female groups (all P>0.05). The thickness of superior muscle group and inferior rectus had not significant difference (2.9±0.7 vs. 3.3±0.8 mm, P=0.162), while the thickness of medial rectus was significantly higher than that of lateral rectus (3.1±0.5 vs. 2.2±0.6 mm, P=0.000). Conclusions The CT measurement of extraocular musculature is simple and time-saving and can be applied in the clinical work. The normative data obtained may be useful in determining pathologic enlargement of the EOMs in both thyroid-associated orbitopathy patients and other various orbital conditions.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Muscles of the Eye
Extraocular Muscles
The six extraocular muscles surround the eyeball and control its movements. They are responsible for a wide range of eye motions, including looking up, down, left, right, and rotating...
Imaging Studies for Cardiovascular System IV: CMRI