In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
Characteristics of a nonocclusive pressure-regulated blood roller pump
1Intensive Care Unit and Perfusion Department, Pediatric Cardiac Surgery, Institut Hospitalier Jacques Cartier, Massy, France. yves.durandy@gmail.com
Abstract:
For decades, extracorporeal life support (ECLS) systems have relied on pumps designed for short-term cardiopulmonary bypass. In the past, occlusive roller pumps were the standard. They are being progressively replaced by centrifugal pumps and devices developed specifically for ECLS. However, the ideal pump for long-term bypass is yet to be created. One interesting alternative is the Rhône-Poulenc 06 pump that is a nonocclusive pressure-regulated blood pump developed in France in the 1970s. This pump is composed of a double-stage rotor with three rollers at each level. The raceway tubing is stretched on the roller and pump occlusivity depends on the tension of the chamber on the rotor. The pump is able to deliver physiological blood flow values without generating dangerous negative or positive pressures. The specific design of the chamber allows the pump to generate a pulsatile flow, inducing minimal blood trauma, and to act as a bubble trap, making it inherently safe. This pump has been used for cardiopulmonary bypass, extracorporeal lung support, and more specifically single-lumen single-cannula venovenous membrane oxygenation for neonates, left-heart or right-heart assist, and venovenous bypass during liver transplant. In conclusion, this old-fashion pump is perfectly adapted for any kind of short- or long-term bypass.
Related Concept Videos
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Bioreactor Controls-I
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Rolling Resistance: Problem Solving
Blood Flow
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific weight or...