Related Experiment Video
Updated: May 15, 2026

A Recovery Cardiopulmonary Bypass Model Without Transfusion or Inotropic Agents in Rats
Published on: March 23, 2018
Comparison between D901 Lilliput 1 and Kids D100 neonatal oxygenators: toward bypass circuit miniaturization
Fabrizio De Rita1, Diego Marchi, Gianluca Lucchese
1Division of Cardiac Surgery, University of Verona, Verona, Italy.
Abstract:
Progress in biomaterial technology and improvements in surgical and perfusion strategy ameliorated morbidity and mortality in pediatric cardiac surgery. In this study, we describe our clinical experience comparing performance of two neonatal oxygenators. From January 2002 to March 2011, 159 infants with less than 5 kg body weight underwent heart surgery. Ninety-four patients received a D901 Lilliput 1 oxygenator with standard bypass circuit (group A), while 65 received a D100 Kids with miniaturized bypass circuit (group B). Miniaturization consisted in shortened arterial, venous, cardioplegia, and pump-master lines. Priming composition consisted in Ringer's acetate solution with addition of albumin and blood, with target hematocrit of 24% or greater. In group B cardiopulmonary bypass (CPB) was vacuum-assisted and started with an empty venous line. Modified ultrafiltration and Cell-Saver blood infusion was routinely applied in both groups. Average ± standard deviation (SD) age at repair was 37 ± 38 days in group A and 59 ± 60 days in group B (P = 0.005). Average ± SD weight, height, and body surface area were 3.5 ± 0.7 kg, 52 ± 4 cm, and 0.22 ± 0.03 m(2) , respectively, in group A, and 3.7 ± 1 kg, 53 ± 5 cm, and 0.23 ± 0.02 m(2) , respectively, in group B (P = not significant [NS]). Male sex was predominant (55 vs. 58%, P = NS). Priming volume was 524 ± 67 mL (group A) and 337 ± 53 mL (group B) (P = 0.001). There were no statistical differences in hemoglobin at the start, during, and at the end of CPB, but group A required higher blood volume added to the prime (111 ± 33 vs. 93 ± 31 mL, P = 0.001). In group B, two surgical procedures were completed in total hemodilution. In group B, CPB time and aortic cross-clamp time were shorter than in group A (106 ± 52 vs. 142 ± 78 min and 44 ± 31 vs. 64 ± 31 min, respectively, P = 0.001). There were 16 hospital deaths in group A and 4 in group B (P = 0.04). Durations of mechanical ventilation and intensive care unit stay were 5.3 ± 3.2 vs. 4.1 ± 3.2 days (P = 0.02) and 6.5 ± 4.9 vs. 5.1 ± 3 days (P = 0.03), respectively. There were significant differences in inotropic score (1083 ± 1175 vs. 682 ± 938, P = 0.04) and blood postoperative transfusion (153 ± 226 vs. 90 ± 61 mL, P = 0.04). Twenty-seven patients in group A and 10 in group B presented with major adverse postoperative complications (P = 0.04). Use of neonatal oxygenators with low priming volume, associated with a miniaturized bypass circuit, seems to be a favorable strategy to decrease postoperative morbidity after cardiac surgery in neonates and infants.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...