Related Experiment Video
Updated: May 15, 2026

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Measurement of retinal oxygen saturation in patients with chronic obstructive pulmonary disease
Stefan Palkovits1, Michael Lasta, Agnes Boltz
1Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria.
Purpose:
There is growing evidence that disturbances in retinal oxygenation may trigger ocular diseases. New instruments allow for the noninvasive measurement of retinal oxygen saturation in humans. The present study was designed to investigate the retinal oxygen saturation in patients with chronic obstructive pulmonary disease (COPD). This was also done in an effort to test the validity of retinal oxygenation measurements with a retinal vessel analyzer.
Methods:
In all, 16 patients with severe COPD grade 4 who were on long-term oxygen treatment were included in the study. For each patient two identical study days were scheduled. Measurements of retinal arterial and venous oxygen saturation were done using a commercially available instrument for retinal oxygen analysis. Peripheral arterial oxygen saturation values were analyzed with pulse oximetry and via a capillary blood sample drawn from the earlobe. Measurements were performed during oxygen treatment and during a period without oxygen supplementation. Analysis of all images for retinal oxygen saturation quantification was done by a masked investigator. Analysis was done using Pearson's correlation and a multivariate regression model.
Results:
Arterial and venous retinal oxygen saturation decreased significantly after the cessation of the oxygen therapy. The arteriovenous oxygen difference was unchanged while breathing ambient air or pure oxygen-enriched air. With both Pearson's correlation and the multivariate model, we found significant positive correlation coefficients between retinal arterial and peripheral arterial oxygen saturation as assessed with pulse oximetry as well as between retinal arterial and peripheral arterial oxygen saturation measured in blood samples. The change of oxygen saturation after discontinuation of oxygen supplementation showed a good correlation between retinal arterial oxygen saturation and peripheral arterial oxygen saturation (r = 0.53, P < 0.05). Reproducibility on the two study days was high.
Discussion:
The present study shows a good correlation between retinal arterial and peripheral arterial oxygen saturation indicating good validity of the technique. (ClinicalTrials.gov number, NCT00999024.).
More Related Videos
08:09Long-term Monitoring of Oxygen Consumption Rates in Highly Differentiated and Polarized Retinal Pigment Epithelial Cultures
Published on: August 16, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...