Performance of hybrid vertical up- and downflow subsurface flow constructed wetlands in treating synthetic high-strength wastewater
Related Experiment Video
Updated: May 15, 2026

Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment
Published on: May 2, 2025
Yong-Jun Zhao1, Pu Cheng, Xi Pei
1Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, People's Republic of China.
Abstract:
The performance and temporal variation of hybrid vertical-subsurface flow constructed wetlands (VFCWs) in response to two-stage combinations of vertical upflow (VUF) and vertical downflow (VDF) were analyzed in this research. The results of high carbon (C) treatment and high nitrogen (N) treatment were similar. The Lythrum salicaria treatment showed higher removal efficiency than CWs planted with Acorus calamus. Under high C- and N-loading treatments, the optimum two-stage combination was VDF-VUF VFCWs planted with A. calamus. Furthermore, the highest nutrient removal efficiencies were achieved in late summer (July and August) and early autumn (September). The chemical oxygen demand and total nitrogen removal efficiencies were significantly affected (P < 0.05) by season, system, and wetland plant.
More Related Videos
08:49Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
Related Concept Videos
Bioreactor Design and Operational System
Biofuels