Optimization and validation of a procedure for the determination of total chromium in postmortem material by ETAAS
Teresa Lech1, Danuta Dudek-Adamska
1Institute of Forensic Research, Westerplatte 9, 31-033 Kraków, Poland. tlech@ies.krakow.pl
Abstract:
A study was conducted to optimize and validate a procedure for the determination of total chromium in wet digested samples of human blood and body tissues for forensic toxicological purposes. Five experimental setups of electrothermal atomic absorption spectrometry (ETAAS) using a Solaar MQZe (Thermo Electron Co.) were compared, using the following: (i) no modifier, (ii) magnesium nitrate, (iii) palladium nitrate, (iv) magnesium and palladium nitrate mixture and (v) palladium nitrate and ammonium dihydrogen phosphate mixture as chemical modifiers. Furthermore, for the mineralization process in the Ethos 1 microwave system (Milestone), it was found that the temperature program suggested by the producer should be improved, thus, four experimental setups are presented. Finally, the whole procedure was validated, obtaining a linear range of calibration from 0.22 to 12.0 µg/L, limit of detection at 0.07 µg/L, limit of quantification at 0.22 µg/L, precision (as relative standard deviation) up to 6%, and accuracy of 98.4-104.4% for the analysis of certified material (ClinChek Whole Blood Control Level III, SRM Whole Blood Level II and III and SRM 1577c Bovine Liver) and within a range from 84.5 to 103.2% for the recovery of spiked samples. It was ascertained that modified wet digestion, followed by ETAAS with magnesium nitrate as a modifier (5 µg) with 1,400/2,500°C as the pyrolysis and atomization temperatures, respectively, can be used to determine chromium at reference levels in biological materials (blood and internal organs) and levels found in chronic or acute poisonings with chromium compounds.
More Related Videos
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...