Effect of Intrafix® SafeSet infusion apparatus on phlebitis in a neurological intensive care unit: a case-control
1Neurological Intensive Care Unit, West China Hospital, Sichuan University, Chengdu, China.
Objective:
To investigate the effect of the Intrafix(®) SafeSet infusion apparatus on the incidence of phlebitis in patients being intravenously infused in a neurological intensive care unit (ICU).
Methods:
Patients aged > 12 years, with no history of diabetes mellitus and no existing phlebitis, requiring a daily peripheral intravenous infusion of ≥ 8 h with the total period lasting ≥ 3 days, were enrolled. Infusions were performed using the Intrafix(®) SafeSet or normal infusion apparatus. Incidence of phlebitis (scored according to the Infusion Nursing Standards of Practice of the American Infusion Nurses Society) was analysed.
Results:
Patients (n = 1545) were allocated to Intrafix(®) SafeSet (n = 709) or normal infusion (n = 836) groups, matched for age, gender and preliminary diagnosis. Incidence of phlebitis was significantly higher using normal infusion apparatus compared with the Intrafix(®) SafeSet (23.4% versus 17.9%, respectively).
Conclusion:
Intrafix(®) SafeSet infusion apparatus significantly reduced the incidence of phlebitis in patients in the neurological ICU, compared with normal infusion apparatus, and may be suitable for use in routine clinical practice.