Related Experiment Video
Updated: May 15, 2026

Quantitative Autoradiographic Method for Determination of Regional Rates of Cerebral Protein Synthesis In Vivo
Published on: June 28, 2019
A novel stable isotope tracer method to measure muscle protein fractional breakdown rate during a physiological
Demidmaa Tuvdendorj1, David L Chinkes, David N Herndon
1Metabolism Unit, Shriners Hospital for Children, Galveston, TX, USA. detuvden@utmb.edu
Abstract:
The measurement of the fractional breakdown rate (FBR) of muscle proteins during physiological non-steady state of amino acids (AAs) presents some challenges. Therefore, the goal of the present experiment was to modify the bolus stable isotope tracer injection approach to determine both fractional synthesis rate (FSR) and FBR of leg muscle protein during a physiological non-steady state of AAs. The approach uses the traditional precursor-product principle but is modified with the assumption that inward transport of AAs is proportional to their plasma concentrations. The FBR value calculated from the threonine tracer served as a reference to evaluate the validity of the FBR measurement from the phenylalanine tracer, which was under a non-steady-state condition due to the concomitant injection of unlabeled phenylalanine. Plasma phenylalanine concentration increased more than fourfold after the bolus injection, and thereafter it decreased exponentially, whereas the threonine concentration remained stable. FBR values were similar with the two tracers [0.133 ± 0.003 and 0.148 ± 0.003%/h (means ± SE) for the phenylalanine and threonine tracers, respectively, P > 0.05]. In addition, FSR values for the two tracers were similar (0.069 ± 0.002 and 0.067 ± 0.001%/h for the phenylalanine and threonine tracers, respectively, P > 0.05), indicating that the traditional FSR approach can also be used in the non-steady state. Accordingly, net balance (NB) values were similar (-0.065 ± 0.002 and -0.081 ± 0.002%/h for the phenylalanine and threonine tracers, respectively, P > 0.05). This new method of measuring muscle protein FBR during physiological non-steady state gives reliable results and allows simultaneous measurement of muscle protein FSR and thus a calculation of NB.
More Related Videos
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
07:41A Method for Measuring Metabolism in Sorted Subpopulations of Complex Cell Communities Using Stable Isotope Tracing
Published on: February 4, 2017