Related Experiment Video
Updated: May 15, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Cryogenic ion mobility-mass spectrometry captures hydrated ions produced during electrospray ionization
Joshua A Silveira1, Kelly A Servage, Chaminda M Gamage
1Texas A&M University, Department of Chemistry, College Station, Texas 77843, United States.
Abstract:
Evaporation of water from extensively hydrated protons and peptides formed by electrospray ionization (ESI) has been examined for the first time by cryogenic ion mobility-mass spectrometry (IM-MS). The extent of hydration was controlled using a heated capillary inlet operated between 340 and 391 K. Cold cluster ions formed in the source region were transported into a low temperature (∼80 K) IM drift tube using an electrostatic ion guide where they were separated on the basis of size-to-charge via low-energy collisions with helium gas. The eluting IM profile was subsequently pulsed into an orthogonal time-of-flight (TOF) mass spectrometer for mass-to-charge (m/z) identification of the cluster ion species. Key parameters that influence the cluster distributions were critically examined including the inlet temperature, drift tube temperature, and IM field strength. In agreement with previous studies, our findings indicate that water evaporation is largely dependent upon the particular charge-carrying species within the cluster. IM-MS results for protonated water clusters suggest that the special stability of H(+)(H(2)O)(n) (n = 21) is attributed to the presence of a compact isomer (assigned to a clathrate cage) that falls below the trendline produced by adjacent clusters in the n = 15 to 35 size range. Peptide studies are also presented in which specific and nonspecific solvation is observed for gramicidin S [GS + 2H](2+)(H(2)O)(n) (n = 0 to ∼26) and bradykinin [BK + 2H](2+)(H(2)O)(n) (n = 0 to ∼73), respectively.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
16:40T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis
Published on: July 31, 2010
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Overview
Mass Spectrometers
Ion-Exchange Chromatography