Dose effects and image quality: is there any influence by bearing devices in whole-body computed tomography in trauma
Björn Loewenhardt1, Robert Hüttinger, Michael Reinert
1Department of Radiology, Herz-Jesu-Hospital of Fulda, Fulda, Germany.
Background:
Stable bearing devices are often utilized by prehospital first responders in modern management of severely injured patients. It is not known whether these devices influence radiation exposure or image quality in whole-body computed tomography (WBCT). Additionally, manufacturers currently provide no specifications concerning these criteria. This investigation analyzed the influence of nine different bearing devices on these specified criteria.
Methods:
The influence of nine different bearing devices on radiation exposure and image quality in WBCT was investigated. The dose-length-product (DLP100) was obtained through use of a CT-ionisation chamber placed in the centre of a 32 cm CT-phantom and compared with a reference value. Moreover, the results were calculated as effective dose data E (mSv). The image quality was assessed by three expert radiologists using the following scoring scale (0=no artefacts; 1=minor artefacts; 2=clearly artefacts; 3=massive artefacts).
Results:
Out of nine bearing devices examined, four showed significantly higher (2.5-4.5%, p<0.05) DLP100 and five showed no significant difference between DLP100 and the reference value. The image quality was classified in the categories "0", "1", "2" and "3" in 4, 3, 1 and 1 case, respectively.
Conclusions:
In diagnostic producers using WBCT, bearing devices may be associated with relevant increases in radiation dose and can affect the image assessability. Some bearing devices are associated with no significant influence on radiation dose and reduction of image quality. Considering all results to get the best balance between image quality and radiation dose, aluminium and metal-free devices should be preferred.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Ultrasonography
During an ultrasonography procedure, a handheld device called a...