Related Experiment Video
Updated: May 15, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Prediction of retention times in temperature programmed gas chromatography using the retention equation derived from
Xiaowei Li1, Guoliang Fan, Cairong Gong
1The School of Material Science and Engineering, Tianjin University, Tianjin 300072, China.
Abstract:
Based on the enlightenment from the crystallization behavior of polymer, a novel retention equation constructed with only three pairs of isothermal retention data was proposed to predict retention times in temperature programmed gas chromatography (TPGC). The new retention equation worked beautifully in both the single- and the multiple-ramp temperature-programmed modes, yielding the average absolute relative errors of 0.65% for single-ramp TPGC across all the 18 analytes in 3 temperature programmed experiments and 0.30% for multiple-ramp TPGC across all the 8 analytes in 6 temperature programmed experiments tested in this work. Moreover, to compare with the new retention equation systematically and thoroughly, another 13 retention equations determined by two or three parameters were derived from a universal formula lnk=a₀+a₁/T+a₂/T²+a₃ lnT+a₄T+a₅T² as a combination of the relationships between lnk and T with reference to four widely used retention equations in publications. Calculated by these 14 retention equations with the same experimental data, the absolute relative errors of prediction retention times for single-ramp TPGC mode were compared by means of statistical analysis. At a very high significance level of 1%, statistical evidences of paired t-test strictly implied that the new retention equation yielded the best prediction results among all of the 14 retention equations. In addition, remarkably, among the 13 retention equations, three seldom used in publications retention equations also worked nicely, yielding satisfactory average absolute relative errors of 0.78%, 0.81% and 0.84% for single-ramp TPGC.
More Related Videos
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatographic Methods: Terminology
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Polymer Classification: Crystallinity
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...

