Related Experiment Video
Updated: May 15, 2026

The Use of an Automated System (GreenFeed) to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals
Published on: September 7, 2015
Using temperature-sensing reticular boluses to aid in the detection of production diseases in dairy cows
A E Adams1, F J Olea-Popelka, I N Roman-Muniz
1Department of Animal Sciences, College of Agricultural Sciences, Colorado State University, Fort Collins CO 80523, USA.
Abstract:
The objective of this study was to investigate associations between increases in reticular temperature (RT) in dairy cows and the diagnosis of metritis, mastitis, lameness, and pneumonia by dairy personnel. A prospective case-control study was conducted on a 2,175-cow dairy operation in Colorado from May 2010 to April 2011. Each cow received an orally administered temperature sensing reticular bolus after parturition and RT measurements were recorded 3 times per day as lactating cows exited the milking parlor. A cow was identified as having an increased RT when a deviation of 0.8°C above baseline (average of readings of previous 10d) was recorded by the TempTrack software (DVM Systems, LLC, Greeley, CO). During the same study period, dairy personnel without access to RT data recorded health events and classified them according to clinical signs observed. A total of 201 health events (cases) were included in the data analysis. Cows with clinical mastitis and pneumonia had significantly higher odds (6.7 and 7.5 times higher, respectively) of having an increased RT of 0.8°C above their baseline within 4d preceding diagnosis when compared with control cows. Specificity and sensitivity for an increase of 0.8°C above baseline RT within 4d of disease diagnosis was 76.85 and 66.97% for mastitis, and 69.23 and 76.92% for pneumonia, respectively. No significant difference in RT was found for cows diagnosed with lameness or metritis. Results of this study suggest that RT monitoring can be a useful tool in the early detection of mastitis and pneumonia in dairy cows.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...