Impact of entropy monitoring on volatile anesthetic uptake
Tarek El Hor1, Philippe Van Der Linden, Stephan De Hert
1Department of Anesthesiology, University Hospital Center of Brugmann, Free University of Brussels, Brussels, Belgium. dr.elhor@gmail.com
Background:
Electroencephalogram-derived monitoring to assess anesthetic depth may allow more accurate hypnotic drug administration, resulting in decreased anesthetic drug consumption. The authors hypothesized that the use of M-Entropy monitoring (Datex-Ohmeda, Helsinki, Finland) is associated with reduced sevoflurane uptake (primary outcome) in patients undergoing major abdominal surgery.
Methods:
A total of 50 patients with an American Society of Anesthesiology score of II-III, scheduled for elective laparoscopic rectosigmoidectomy were randomized into two groups in this randomized controlled trial. In the control group, the target expiratory fraction of sevoflurane was adapted according to standard clinical practice. In the study group, the target expiratory fraction of sevoflurane was adapted to maintain state entropy values between 40 and 60. State entropy values were continuously recorded in both groups but were not available to the anesthesiologist in the control group. In both groups, patients were ventilated using the auto-control mode of the Zeus® (Dräger, Lübeck, Germany) respirator, which allows precise measurements of sevoflurane uptake. Sufentanil was administered using a target-controlled infusion system.
Results:
Demographics did not differ between groups. During the anesthesia maintenance phase, state entropy values were lower in the control group than the study group (P < 0.0001). Sevoflurane uptake was higher in the control group than the study group (5.2 ± 1.4 ml/h vs. 3.8 ± 1.5 ml/h; P = 0.0012). Three patients in the control group developed intraoperative hypotension compared with none in the study group (P = 0.03).
Conclusions:
Monitoring the depth of anesthesia using M-Entropy was associated with a significant reduction in sevoflurane uptake.
More Related Videos
08:16Optogenetic Activation of Afferent Pathways in Brain Slices and Modulation of Responses by Volatile Anesthetics
Published on: July 23, 2020
03:02Application of Dixon's Up-and-Down Design to Estimate the Minimum Alveolar Concentration of Sevoflurane in Rats with Refined Movement Classification
Published on: July 25, 2025
Related Concept Videos
Inhalational Anesthetics: Overview
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Parenteral Anesthetics: Overview
Stages of General Anesthesia
Local Anesthetics: Pharmacokinetics
Local Anesthetics: Adverse Effects
Once absorbed into the systemic circulation, local anesthetics can affect the organs that depend on the functioning of sodium...