Neonatal screening for critical cardiovascular anomalies using pulse oximetry
Sarah Prudhoe1, Majd Abu-Harb, Sam Richmond
1Consultant Neonatologist, Sunderland Royal Hospital, Neonatal Unit, Sunderland Royal Hospital, Sunderland, UK. Majd.Abuharb@newcastle.ac.uk
Introduction:
Babies with cardiac anomalies are often asymptomatic at birth, and many remain undetected despite routine newborn examination. We retrospectively assessed the effect of routine pulse oximetry in detection of such anomalies from a hospital birth population of 31 946 babies born between 1 April 1999 and 31 March 2009.
Method:
29 925 babies who were not admitted to the neonatal unit at birth underwent postductal oxygen saturation measurement before discharge. If saturation was below 95% an examination was performed. If this was abnormal or saturation remained low, an echocardiogram was performed. All babies with cardiac anomaly diagnosed before 1-year were identified from the region's fetal abnormality database.
Results:
Critical anomalies affected 27 infants (1 in 1180); 10 identified prenatally, 2 after echocardiogram was performed because of other anomalies, 2 in preterm infants, 2 when symptomatic before screening, 5 by oximetry screening, 1 when symptomatic in hospital after a normal screen and 5 after discharge home. Serious anomalies affected 50 infants (1 in 640); 8 identified antenatally, 7 because of other anomalies, 3 in the neonatal unit, 5 by pulse oximetry screening, 11 by routine newborn examination, and 16 after discharge home.
Conclusions:
Routine pulse oximetry aided detection of 5/27 of critical and 5/50 of serious anomalies in this sample, but did not prevent five babies with critical and 15 with serious anomalies being discharged undiagnosed. Results from screening over 250 000 babies have now been published, but this total includes only 49 babies with transposition, and even smaller numbers of rarer anomalies.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: