Infant cardiac magnetic resonance imaging using oscillatory ventilation: safe and effective

Alicia H Chaves1, Joseph R Cava, Pippa Simpson

  • 1The Herma Heart Center, Children's Hospital of Wisconsin, Medical College of Wisconsin, Milwaukee, WI 53226, USA. achaves@peds.umaryland.edu

Pediatric Cardiology
|January 25, 2013
PubMed

Insights

High-frequency oscillatory ventilation (HFOV) offers a safe alternative to conventional methods for pediatric cardiac magnetic resonance imaging (CMR). This technique eliminates the need for breath-holding, ensuring comparable image quality and fewer complications.

Area of Science:

  • Pediatric Cardiology
  • Medical Imaging
  • Respiratory Physiology

Background:

  • Pediatric cardiac magnetic resonance imaging (CMR) often necessitates sedation or general anesthesia.
  • Conventional ventilation techniques with breath-holding can cause respiratory artifacts and complications like atelectasis.

Purpose of the Study:

  • To evaluate the feasibility, safety, and efficacy of high-frequency oscillatory ventilation (HFOV) during pediatric CMR.
  • To compare image quality and scan times between HFOV and conventional ventilation with breath-holding.

Main Methods:

  • Retrospective analysis of 8 infants undergoing CMR with HFOV versus 8 controls with conventional ventilation and breath-holding.
  • Image quality assessed by blinded cardiologists.
  • Demographic data, adverse events, and scan acquisition times recorded.

Main Results:

  • No significant differences in patient characteristics or average image quality (cine short-axis, black blood imaging) between groups.
  • HFOV group showed significantly faster acquisition of short-axis cine stacks (1.8 vs. 5.0 min).
  • No adverse events in the HFOV group; two conventional ventilation scans were terminated early.

Conclusions:

  • High-frequency oscillatory ventilation (HFOV) is a feasible and well-tolerated method for pediatric CMR.
  • HFOV provides equivalent image quality to conventional ventilation with breath-holding.
  • HFOV facilitates shorter scan times for specific CMR sequences and reduces the risk of scan termination due to complications.

Related Concept Videos

Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
Cardiopulmonary Resuscitation II: ACLS Airway Management01:22

Cardiopulmonary Resuscitation II: ACLS Airway Management

Airway management is a key skill in emergency and critical care settings, as maintaining a clear airway is essential for adequate oxygenation and ventilation.Head Tilt-Chin Lift TechniqueThe head tilt-chin lift maneuver is an essential technique primarily used in patients without suspected cervical spine injuries. To perform this maneuver, one hand is placed on the patient’s forehead, and gentle pressure is applied backward to tilt the head. The fingertips of the other hand are positioned under...
Assessment of Ventilation I: Respiratory Rate01:20

Assessment of Ventilation I: Respiratory Rate

Assessment of Ventilation
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: