Detection of pulmonary nodules at paediatric CT: maximum intensity projections and axial source images are
Fleur Kilburn-Toppin1, Owen J Arthurs, Angela D Tasker
1Department of Radiology, Addenbrooke's Hospital, Cambridge University Teaching Hospitals NHS Foundation Trust, Box 219, Hills Road, Cambridge, CB2 0QQ, UK. p.set@addenbrookes.nhs.uk
Background:
Maximum intensity projection (MIP) images might be useful in helping to differentiate small pulmonary nodules from adjacent vessels on thoracic multidetector CT (MDCT).
Objective:
The aim was to evaluate the benefits of axial MIP images over axial source images for the paediatric chest in an interobserver variability study.
Materials And Methods:
We included 46 children with extra-pulmonary solid organ malignancy who had undergone thoracic MDCT. Three radiologists independently read 2-mm axial and 10-mm MIP image datasets, recording the number of nodules, size and location, overall time taken and confidence.
Results:
There were 83 nodules (249 total reads among three readers) in 46 children (mean age 10.4 ± 4.98 years, range 0.3-15.9 years; 24 boys). Consensus read was used as the reference standard. Overall, three readers recorded significantly more nodules on MIP images (228 vs. 174; P < 0.05), improving sensitivity from 67% to 77.5% (P < 0.05) but with lower positive predictive value (96% vs. 85%, P < 0.005). MIP images took significantly less time to read (71.6 ± 43.7 s vs. 92.9 ± 48.7 s; P < 0.005) but did not improve confidence levels.
Conclusion:
Using 10-mm axial MIP images for nodule detection in the paediatric chest enhances diagnostic performance, improving sensitivity and reducing reading time when compared with conventional axial thin-slice images. Axial MIP and axial source images are complementary in thoracic nodule detection.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...