Untargeted and targeted comprehensive two-dimensional GC analysis using a novel unified high-speed triple quadrupole
Peter Quinto Tranchida1, Flavio Antonio Franchina, Mariosimone Zoccali
1Dipartimento Farmaco-chimico, Facoltà di Farmacia, Università degli Studi di Messina, viale Annunziata, 98168 Messina, Italy.
Abstract:
The present manuscript is focused on the evaluation of a novel high-speed triple quadrupole mass spectrometer (QqQ MS), carried out under extreme GC conditions, namely those generated by a flow-modulated (FM) comprehensive two-dimensional GC (GC×GC) system. The novel QqQ MS system is capable of operation under high speed conditions, in both full-scan (maximum scan speed: 20,000 amu/s) and multiple reaction monitoring (MRM) modes. Moreover, the QqQ MS instrument can generate simultaneous full scan/MRM data, also in a very rapid manner. An FM GC × GC-MSMS method was developed for the simultaneous full-scan qualitative analysis of untargeted essential oil compounds, and MRM quali/quantitative analysis of targeted ones, namely three preservatives [o-phenylphenol (OPP), butylated hydroxytoluene (BHT), butylated hydroxyanisole (BHA)]. The QqQMS system generated a sufficient number of data points per peak, for both qualitative and quantitative purposes. The degree of sensitivity, reached through the MRM analysis, widely exceeded current-day regulations. Method validation, related to the MRM analysis, was performed considering retention time, peak area and ion ratio repeatability, limits of detection and quantification, and accuracy. Additionally, a spearmint essential oil was spiked with 5 phytosanitary compounds at the 1 ppb level, and analysed through an MRM-only GC × GC-MSMS application. Emphasis was devoted not only on sensitivity (satisfactory for all the contaminants), but also on the importance of precursor ion selection, and of the GC × GC separation process. Finally, sensitivity was compared between the MRM and SIM modes, in scan/MRM, MRM, scan/SIM and SIM analyses, performed on a mixture of 22 phytosanitary products, at a concentration level in the 50-150 ppb range.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Mass Analyzers: Common Types
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Resolution Mass Spectrometry (HRMS)