Related Experiment Video
Updated: May 14, 2026

Post-Myocardial Infarction Heart Failure in Closed-chest Coronary Occlusion/Reperfusion Model in Göttingen Minipigs and Landrace Pigs
Published on: April 17, 2021
Off-pump anteroapical aneurysm plication following left ventricular postinfarction aneurysm: effect on cardiac
Xin-sheng Huang1, Cheng-xiong Gu, Jun-feng Yang
1The Department of Cardiac Surgery, Beijing An Zhen Hospital, Capital Medical University, Beijing, China.
Background:
In patients with coronary disease and aneurysm, ventricular reconstruction with revascularization is a surgical option. Details of patient selection and optimal surgical technique are still debated. We report our results with off-pump aneurysm plication after ventricular aneurysm with relative wall thinning.
Methods:
We retrospectively reviewed the records of 248 patients who had an operation for postinfarction left ventricular aneurysm. Reconstruction was accomplished by off-pump anteroapical aneurysm plication. The following variables were recorded: preoperative clinical, angiographic and echocardiographic findings and operative procedures. Outcomes were early mortality, long-term survival and poor 5-year result, defined as the need for transplantation or repeated hospitalization for congestive heart failure. Risk factors were pinpointed using the t test and survival curves. Independent risk factors were identified using Cox regression methods.
Results:
Hospital mortality was low (2.0%). Mean follow-up was 5.8 (standard deviation [SD] 3.8) years. Actuarial survival at 1 and 5 years was 94% and 84%. Among the 232 survivors, 200 were in functional class I or II, and the average increase in ejection fraction was 14.0% (SD 3.1%). As determined by multivariable analysis, factors predicting poor outcome were advanced age, ejection fraction less than 0.35, conicity index less than 1, end-systolic volume index greater than 80 mL/m2, advanced New York Heart Association functional class and congestive heart failure.
Conclusion:
Using wall thinning as a criterion for patient selection, the technique of off-pump anteroapical aneurysm plication can be performed with low operative mortality and provides good symptomatic relief and long-term survival.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aortic Regurgitation III: Medical Management
Cardiomyopathy V: Interprofessional Care