An electrocardiogram-based analysis evaluating sleep quality in patients with obstructive sleep apnea
John Harrington1, Preetam J Schramm, Charles R Davies
1Division of Sleep Medicine, National Jewish Health, 1400 Jackson St, Denver, CO 80206-2762, USA. HarringtonJ@NJHealth.org
Objective:
The study compares polysomnography (PSG) and cardiopulmonary coupling (CPC) sleep quality variables in patients with (1) obstructive sleep apnea (OSA) and (2) successful and unsuccessful continuous positive airway pressure (CPAP) response.
Patients/Methods:
PSGs from 50 subjects (32 F/18 M; mean age 48.4 ± 12.29 years; BMI 34.28 ± 9.33) were evaluated. OSA patients were grouped by no (n = 16), mild (n = 13), and moderate to severe (n = 20) OSA (apnea-hypopnea index (AHI) ≤ 5, >5-15, >15 events/h, respectively). Outcome sleep quality variables were sleep stages in non-rapid eye movement, rapid eye movement sleep, and high (HFC), low (LFC), very low-frequency coupling (VLFC), and elevated LFC broad band (e-LFCBB). An AHI ≤ 5 events/h and HFC ≥ 50 % indicated a successful CPAP response. CPC analysis extracts heart rate variability and QRS amplitude change that corresponds to respiration. CPC-generated spectrograms represent sleep dynamics from calculated coherence product and cross-power of both time series datasets.
Results:
T tests differentiated no and moderate to severe OSA groups by REM % (p = 0.003), HFC (p = 0.007), VLFC (p = 0.007), and LFC/HFC ratio (p = 0.038) variables. The successful CPAP therapy group (n = 16) had more HFC (p = 0.003), less LFC (p = 0.003), and e-LFCBB (p = 0.029) compared to the unsuccessful CPAP therapy group (n = 8). PSG sleep quality measures, except the higher arousal index (p = 0.038) in the unsuccessful CPAP group, did not differ between the successful and unsuccessful CPAP groups. HFC ≥ 50 % showed high sensitivity (77.8 %) and specificity (88.9 %) in identifying successful CPAP therapy.
Conclusions:
PSG and CPC measures differentiated no from moderate to severe OSA groups and HFC ≥ 50 % discriminated successful from unsuccessful CPAP therapy. The HFC ≥ 50 % cutoff showed clinical value in identifying sleep quality disturbance among CPAP users.
More Related Videos
04:33Association Between Sleep Quality and Cognitive Symptoms in Patients with Major Depressive Disorder
Published on: April 26, 2024
05:34Auricular Acupuncture as a Traditional Chinese Medicine Therapy for Chronic Obstructive Pulmonary Disease Combined with Sleep Disorders
Published on: August 18, 2023
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Dysrhythmias V: Evaluating Dysrhythmias
Sleep-Wake Cycles
NREM Sleep
NREM sleep comprises four progressive stages that seamlessly merge: