Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Hybrid preconcentrator/focuser module for determinations of explosive marker compounds with a micro-scale gas
Gustavo Serrano1, Thitiporn Sukaew, Edward T Zellers
1Department of Environmental Health Sciences, University of Michigan, Ann Arbor, MI 48109-2029, USA.
Abstract:
This article describes the development and characterization of a partially selective preconcentrator/focuser (PCF) module for a field-portable micro-scale gas chromatograph (μGC) designed to rapidly determine trace levels of two vapor-phase markers of the explosive trinitrotoluene (TNT): 2,3-dimethyl-2,3-dinitrobutane (DMNB) and 2,4-dinitrotoluene (2,4-DNT). The PCF module has three primary components. The first is a high-volume sampler, comprising a resistively-heated 6-cm long stainless steel tube packed with tandem beds of the graphitized carbons Carbopack B (C-B, 30 mg) and Carbopack Y (C-Y, 15 mg), which traps the markers but permits more volatile interferences to pass through largely unretained. The second component is a microfocuser (μF), comprising a 4.2×9.8 mm Si chip containing a deep-reactive-ion-etched (DRIE) cavity packed with 2mg of C-B, a Pyrex cap, integrated heaters, and etched fluidic channels. The third component is a commercial polymer-membrane filter used as a pre-trap to remove particles and adsorbed low volatility interferences. Markers captured in the sampler are thermally desorbed and transferred to the μF, and then thermally desorbed/injected from the μF into a downstream separation (micro)column and detected. Scrubbed ambient air is used as carrier gas. The adsorbent capacities, baseline temperatures, sampling and desorption flow rates, and heating profiles were optimized for each PCF module component while minimizing the analysis time. An overall transfer efficiency of 86% was achieved at marker concentrations of ~0.2-2.6 ppb. In the final configuration the PCF module requires just 60s to collect a 1-L sample (3 L/min), focus (40 mL/min), and inject the markers (3 mL/min), producing half-maximum injection peak widths of ~2 and 5 s, and preconcentration factors of 4500 and 1800, for DMNB and 2,4-DNT, respectively.
More Related Videos
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...