Related Experiment Video
Updated: May 14, 2026

08:18
Engineered Vascularized Muscle Flap
Published on: January 11, 2016
Below-knee amputation with a vascularized fibular graft and headless compression screw
Benjamin J Brown1, Matthew L Iorio, Lauren Hill
1Washington, D.C.; and Plainsboro, N.J. From MedStar Georgetown University Hospital and Integra LifeSciences.
Plastic and Reconstructive Surgery
|January 30, 2013
Summary
The Ertl modification for below-knee amputation creates a bone bridge, improving prosthetic torque transmission and distal weight bearing. This technique enhances prosthetic design and function for amputees.
Area of Science:
- Orthopedic Surgery
- Biomedical Engineering
Background:
- Below-knee amputations can result in free rotation and translation of the distal tibia and fibula.
- This instability limits effective torque transmission to the prosthesis.
- Current prosthetic designs may be restricted by the anatomy of the residual limb.
Purpose of the Study:
- To describe a surgical technique for distal tibiofibular bridging (Ertl modification) in below-knee amputation.
- To detail the use of a vascularized fibular segment and a headless compression screw in this procedure.
- To highlight the benefits of improved torque transmission and prosthetic versatility.
Main Methods:
- Surgical technique involving the Ertl modification for below-knee amputation.
- Utilizing a segment of vascularized fibula to create a bone bridge between the tibia and fibula.
- Employing a headless compression screw for stable fixation of the fibular segment.
Main Results:
- The Ertl modification establishes a bone bridge, enhancing stability of the distal tibia and fibula.
- This anatomical modification facilitates improved transmission of torque from the femur to the prosthesis.
- The technique allows for increased distal weight bearing and supports more versatile prosthetic designs.
Conclusions:
- Distal tibiofibular bridging via the Ertl modification offers significant biomechanical advantages for below-knee amputees.
- The described technique using a vascularized fibular segment and compression screw provides a stable and effective solution.
- This surgical approach can lead to improved prosthetic function and patient outcomes.