Radio-frequency ionization of organic compounds for mass spectrometry analysis

Behrooz Zekavat1, Touradj Solouki

  • 1Department of Chemistry and Biochemistry, Baylor University, Waco, TX 76798, USA.

Related Concept Videos

Mass Spectrometry: Overview01:19

Mass Spectrometry: Overview

Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electron ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave behind a...
Mass Spectrometers01:16

Mass Spectrometers

This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Mass Spectrometry: Aromatic Compound Fragmentation01:23

Mass Spectrometry: Aromatic Compound Fragmentation

Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...