Related Experiment Video
Updated: May 14, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Joint probability of shape and image similarities to retrieve 2D TRUS-MR slice correspondence for prostate biopsy
1Le2i CNRS-UMR 6306, Université de Bourgogne, Le Creusot, France. jhimli.mitra@u-bourgogne.fr
Abstract:
This paper presents a novel method to identify the 2D axial Magnetic Resonance (MR) slice from a pre-acquired MR prostate volume that closely corresponds to the 2D axial Transrectal Ultrasound (TRUS) slice obtained during prostate biopsy. The method combines both shape and image intensity information. The segmented prostate contours in both the imaging modalities are described by shape-context representations and matched using the Chi-square distance. Normalized mutual information and correlation coefficient between the TRUS and MR slices are computed to find image similarities. Finally, the joint probability values comprising shape and image similarities are used in a rule-based framework to provide the MR slice that closely resembles the TRUS slice acquired during the biopsy procedure. The method is evaluated for 20 patient datasets, of which 18 results match at least one of the two clinical expert choices.