Related Experiment Video
Updated: May 14, 2026

Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
Quantitative assessment of left ventricular diastolic function via longitudinal and transverse flow impedances
1Department of Biomedical Engineering, School ofEngineering and Applied Sciences, Washington University in St. Louis, MO 63130, USA. eghosh@wustl.edu
Abstract:
Flow impedance has been used to characterize the physical properties of the vascular system by assessing its phasic flow response to pulsatile pressure input in terms of resistance as a function of frequency. Impedance has also been used to characterize global diastolic left ventricular (LV) chamber properties. In early diastole the LV is a mechanical suction pump and accommodates filling by simultaneously expanding in two principal spatial directions: longitudinal (base-to-apex, long-axis) and transverse (radial, short-axis). Total (characteristic) impedance Z(C) is the product of longitudinal (Z(L)) and transverse (Z(T)) impedance as Z(C)(2)=Z(L)Z(T) where the two impedances reflect the relative spatial propensity for volume accommodation. In this work we compute Z(L) and Z(T) for the LV in early diastole. We analyze simultaneously recorded dual pressure-transducer and transthoracic echocardiographic flow data obtained during cardiac catheterization in 11 subjects. We found that Z(L) was 2 orders of magnitude smaller than Z(T) in all subjects, providing the first hemodynamic evidence, in concordance with cine-MRI imaging data that longitudinal volume accommodation is indeed, nature's preferred spatial filling mechanism. We also investigated the effect of impaired diastolic function on directional impedances and found that Z(L) increased (becomes worse) while Z(T) decreased (becomes better) indicating that as diastolic function becomes impaired radial filling compensates for decreased longitudinal volume accommodation to preserve stroke volume. These results provide mechanistic insight and show that normal diastolic function defines a properly impedance matched state and that diastolic dysfunction is equivalent to a state of impedance mismatch.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017