Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Evaluation of radon progeny mitigation techniques (HEPA filtration, ionization, electrostatic deposition) and their potential use in caves.

Journal of environmental radioactivity·2026
Same author

MONTE CARLO STUDY OF NEUTRON SPECTRA UNFOLDING FOR A PROTON BEAM USING MLEM.

Radiation physics and chemistry (Oxford, England : 1993)·2026
Same author

Comparison of OSL and TL dosimetry systems against IEC and ICRP standards.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2023
Same author

Multidisciplinary treatment may avoid pelvic exenteration in rectovesical fistula due to locally advanced rectal cancer.

Revista de gastroenterologia de Mexico (English)·2022
Same author

Reply to: Role of ambient humidity underestimated in research on correlation between radioactive decay rates and space weather.

Scientific reports·2022
Same author

Lipid Composition Analysis Reveals Mechanisms of Ethanol Tolerance in the Model Yeast <i>Saccharomyces cerevisiae</i>.

Applied and environmental microbiology·2021
Same journal

Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
See all related articles

Related Experiment Video

Updated: May 14, 2026

In Situ Detection and Single Cell Quantification of Metal Oxide Nanoparticles Using Nuclear Microprobe Analysis
14:53

In Situ Detection and Single Cell Quantification of Metal Oxide Nanoparticles Using Nuclear Microprobe Analysis

Published on: February 3, 2018

X-ray simulation with the Monte Carlo code PENELOPE. Application to Quality Control.

F Pozuelo1, S Gallardo, A Querol

  • 1Ingeniería Química y Nuclear department, Universitat Politècnica de València, València, Spain. faupona@etsii.upv.es

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
|February 1, 2013
PubMed
Summary
This summary is machine-generated.

Simulating X-ray spectra using Monte Carlo codes like PENELOPE aids quality control (QC) for X-ray tubes. Optimizing simulation parameters, such as the FORCE factor, balances accuracy with computational time for dose reduction.

More Related Videos

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

Related Experiment Videos

Last Updated: May 14, 2026

In Situ Detection and Single Cell Quantification of Metal Oxide Nanoparticles Using Nuclear Microprobe Analysis
14:53

In Situ Detection and Single Cell Quantification of Metal Oxide Nanoparticles Using Nuclear Microprobe Analysis

Published on: February 3, 2018

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

Area of Science:

  • Medical Physics
  • Computational Physics

Background:

  • Accurate X-ray energy spectrum knowledge is crucial for X-ray tube quality control (QC) to minimize patient radiation dose.
  • Routine QC often measures indirect parameters due to the challenges of direct X-ray spectrum measurement.

Purpose of the Study:

  • To evaluate Monte Carlo simulation codes (PENELOPE, MCNP5) as tools for verifying QC parameters.
  • To simulate X-ray spectra, considering equipment specifics, and compare them with theoretical models.
  • To perform a sensitivity analysis of simulation parameters influencing spectral accuracy and computational efficiency.

Main Methods:

  • Utilized PENELOPE and MCNP5 Monte Carlo codes to simulate X-ray spectra, including Bremsstrahlung and characteristic X-rays.
  • Compared simulated spectra against the theoretical IPEM 78 spectrum.
  • Conducted a sensitivity analysis to identify key parameters affecting simulation outcomes, focusing on the FORCE factor.

Main Results:

  • The FORCE factor was identified as the most influential parameter in PENELOPE simulations, significantly impacting computer time.
  • Optimizing the FORCE factor is essential for achieving agreement between simulated and theoretical spectra while reducing computation time.
  • The PENELOPE model can determine quality parameters like Half Value Layer (HVL), though high FORCE values increase computation time; depth dose assessment is feasible with lower FORCE values.

Conclusions:

  • Monte Carlo simulations offer a viable method for verifying X-ray tube QC parameters.
  • Careful optimization of simulation parameters, particularly the FORCE factor, is necessary to balance accuracy and computational efficiency.
  • The developed PENELOPE model shows potential for various QC applications, with parameter tuning critical for specific quality metrics.