Related Experiment Video
Updated: May 14, 2026

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Induced spiral motion in cardiac tissue due to alternans
Taylor Cameron1, Jörn Davidsen
1Complexity Science Group, Department of Physics and Astronomy, University of Calgary, Calgary, Alberta T2N 1N4, Canada.
Abstract:
Spiral wave meander is a typical feature observed in cardiac tissue and in excitable media in general. Here, we show for a simple model of excitable cardiac tissue that a transition to alternans--a beat-to-beat temporal alternation in the duration of cardiac excitation--can also induce a transition in the spiral core motion that is related to the presence of synchronization defect lines (SDLs) or nodal lines. While this is similar to what has been predicted and indeed observed for complex-oscillatory media close to onset, we find important qualitative differences. For example, single straight SDLs rotate and induce an additional nonresonant frequency characterizing the core motion of the attached spiral. We analyze this behavior quantitatively as a function of the steepness of the restitution curve and show that the velocity and the directionality of the core motion vary monotonically with the control parameter. Our findings agree with recent observations in rat heart tissue cultures indicating that the described behavior is of rather general nature. In particular, it could play an important role in the context of potentially life-threatening cardiac arrhythmias such as fibrillation for which alternans and spiral waves are known precursors.
Related Concept Videos
Mechanism of Cardiac Arrhythmias
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Electrophysiology of Normal Cardiac Rhythm
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...