Related Experiment Video
Updated: May 14, 2026

Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy
Published on: June 16, 2022
Ureteral rupture from aberrant Foley catheter placement: a case report
Kevin S Baker1, Bari Dane, Yudell Edelstein
1Department of Radiology, Stony Brook University Medical Center, Stony Brook, NY 11794, USA. Kevin.Baker@sbumed.org
Abstract:
We present the case of a 59 year old female with history of severe neurologic dysfunction from advanced multiple sclerosis who presented with lethargy and oliguria several hours after urethral Foley catheterization. A contrast-enhanced CT scan of the abdomen/pelvis showed an aberrantly placed Foley catheter with its balloon inflated in the proximal left ureter, a rare complication of Foley catheterization with only 5 other cases reported. Incomplete ureteral rupture was demonstrated and confirmed by a followup CT scan in the urographic phase. One of our institution's Interventional Radiologists then placed a nephroureteral stent across the injured ureter to facilitate healing. The patient expired 9 days after the procedure from unrelated sepsis from a chronic stage IV decubitus ulcer, so long term monitoring could not be performed. Following description of our case, we conduct a literature review of presentations, imaging characteristics, and treatment of ureteral Foley catheter placement.
Related Concept Videos
Urinary Tract Calculi VI: Surgical Management
Urinary Tract Calculi II: Pathophysiology and Clinical Manifestations
Urinary Tract Calculi V: Nursing Management
Acute Pyelonephritis I: Introduction
Urinary Tract Calculi III: Medical Management
Urinary Tract Infection II: Pathophysiology