Undisclosed and undetected foreign bodies during MRI screening resulting in a potentially serious outcome
Cynthia A James1, Alexandra Karacozoff, Frank G Shellock
1Louis A. Johnson VA Medical Center, Clarksburg, WV 26301, USA. cynthia.james4@va.gov
Abstract:
The risks associated with performing magnetic resonance imaging (MRI) examinations in patients with ferromagnetic foreign bodies are well known. Accordingly, screening procedures are implemented to identify items that may pose hazards to patients and other individuals before allowing them to enter the MRI system room. This report describes a patient who, despite undergoing proper MRI screening procedures, did not disclose the presence of ferromagnetic foreign bodies, which resulted in a potentially serious outcome.
Insights
Proper screening for magnetic resonance imaging (MRI) is crucial. A patient experienced a potentially serious outcome due to undisclosed ferromagnetic foreign bodies, highlighting gaps in safety protocols.
Area of Science:
- Radiology
- Medical Imaging Safety
- Biomedical Engineering
Background:
- Magnetic resonance imaging (MRI) utilizes powerful magnetic fields, posing risks to patients with ferromagnetic foreign bodies.
- Standard screening protocols aim to identify and remove hazardous metallic objects before MRI examinations.
- Ensuring patient safety during MRI requires rigorous adherence to and verification of screening procedures.
Observation:
- This report details a case where a patient, despite undergoing standard MRI screening, failed to disclose the presence of ferromagnetic foreign bodies.
- The undisclosed foreign bodies posed a significant risk during the magnetic resonance imaging procedure.
- The patient's failure to disclose potentially hazardous material led to a near-miss incident.
Findings:
- Even with established screening protocols, patient disclosure remains a critical vulnerability in preventing MRI-related accidents.
- Ferromagnetic foreign bodies can cause severe injury or device malfunction within the MRI environment.
- The case underscores the need for enhanced vigilance and potentially alternative methods to ensure complete screening.
Implications:
- Healthcare providers must reinforce the importance of complete disclosure during MRI screening.
- Further research into non-invasive methods for detecting undisclosed ferromagnetic materials may be warranted.
- This incident highlights the ongoing challenge of maintaining absolute safety in advanced medical imaging environments.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
X-ray Imaging