Temperature profile of radiofrequency probe application in wrist arthroscopy: monopolar versus bipolar
Michaela Huber1, Christoph Eder, Michael Mueller
1Department of Trauma, Plastic & Hand Surgery, University Medical Center Regensburg, Regensburg, Germany. michaela1.huber@klinik.uni-regensburg.de
Purpose:
The purpose of this study was to investigate the changes in temperature during wrist arthroscopy comparing monopolar and bipolar radiofrequency energy (RFE).
Methods:
A standard wrist arthroscopy was performed on 14 arms of 7 cadavers without irrigation or with continuous irrigation with 0.9% saline solution and gravity-assisted outflow through an 18-gauge needle. We treated 7 wrists with a bipolar device (VAPR II with 2.3-mm side effect electrodes; DePuy Mitek, Westwood, MA) and 7 wrists with a monopolar device (OPES Ablator for small joints, 45°; Arthrex, Naples, FL). The temperature was recorded simultaneously from 7 predefined anatomic landmarks.
Results:
We observed an increase in the temperature corresponding to the time of energy application. The highest measured peak temperatures were 52°C (monopolar) and 49.5°C (bipolar) without irrigation. Continuous irrigation led to a significant reduction in the temperature at the site of the energy application. The mean temperature decreased by 7°C for the monopolar system and 5°C for the bipolar system when irrigation was used. For both radiofrequency devices, we found a decrease in the temperature proportional to the distance of the sensors to the radiofrequency probe.
Conclusions:
Monopolar and bipolar RFE can be safely used in wrist arthroscopy if a continuous irrigation system is applied and the energy impulse does not exceed 5 to 10 seconds. However, it should be used with great care to avoid local heat damage especially at the cartilage.
Clinical Relevance:
This basic science study was performed to gain data concerning the temperature in wrist arthroscopy and to broaden the knowledge about the risks when using RFE. Furthermore, we sought to control side effects of RFE by finding the best applied form of RFE regarding duration and pulsation (monopolar/bipolar).
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation