A practical method of measuring oxygen consumption in children with complex mixing circulations by the use of

Daryl I Schantz1, Robert P Chen

  • 1Department of Pediatric Cardiology, Dalhousie University, Halifax, Nova Scotia, Canada.

Insights

Predicting oxygen consumption (VO2) using standard formulas is unreliable in patients with bidirectional cavopulmonary anastomosis (BDCPA). Measured VO2 is essential for accurate pulmonary vascular resistive index (PVRI) assessment in this complex circulation group.

Area of Science:

  • Cardiology
  • Pediatric Cardiology
  • Cardiovascular Physiology

Background:

  • Complex congenital heart disease often involves altered hemodynamics.
  • Patients with bidirectional cavopulmonary anastomosis (BDCPA) present unique circulatory challenges.
  • Accurate assessment of oxygen consumption (VO2) is crucial for managing these patients.

Purpose of the Study:

  • To describe a method for measuring VO2 and pulmonary vascular resistive index (PVRI) using thermodilution cardiac output.
  • To evaluate the reliability of predicted VO2 formulas in patients with BDCPA.
  • To determine the correlation between measured VO2 and other hemodynamic parameters.

Main Methods:

  • Cardiac catheterization data from 25 patients with BDCPA were reviewed.
  • Thermodilution cardiac output was used to calculate VO2 and PVRI.
  • Correlations between predicted and measured VO2, and other hemodynamic parameters, were analyzed.

Main Results:

  • No significant correlation was found between predicted and measured VO2 (r = -0.258, P = 0.21).
  • A strong correlation was observed between the difference and the measured VO2 (r = 0.963, P < .0001), indicating formula unreliability.
  • Body surface area and mixed venous oxygen content showed no significant or weak correlation with measured VO2, respectively.

Conclusions:

  • Predicted VO2 formulas are unreliable for assessing PVRI in BDCPA patients.
  • No single hemodynamic parameter reliably correlates with VO2 in this population.
  • Direct measurement of VO2 is necessary for accurate PVRI determination in patients with BDCPA.