Related Experiment Video
Updated: May 14, 2026

Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
Feasibility and validity of self-reported walking capacity in patients with intermittent claudication
Garry Tew1, Robert Copeland, Alexis Le Faucheur
1Sheffield Hallam University, Sheffield, United Kingdom.
Objective:
The primary aim of this study was to assess if self-reported measures of walking limitation correlate better with a community-based assessment of maximum walking distance (MWD) than they do with laboratory-based tests in patients with intermittent claudication. A secondary aim was to examine the effect of prior objective testing on these correlations.
Methods:
Thirty-one patients completed three self-report tools (self-reported MWD; Walking Impairment Questionnaire [WIQ]; Estimation of Ambulatory Capacity by History-Questionnaire [EACH-Q]) immediately before and approximately 1 week after a series of objective tests (incremental treadmill walking test, 6-minute walk test, 1-hour global positioning system [GPS] recording of a community walk). We analyzed the feasibility of the self-report tools in terms of number of errors and their correlation (r) with objective measures.
Results:
The correlations of self-report tests to GPS-MWD (range, .579-.808) were consistently higher than with the treadmill test (range, .310-.584) and 6-minute walk test (range, .414-.613). The WIQ had the highest proportion of errors, both at first and second completion (58% and 42%, respectively), compared with self-reported MWD (23% and 13%, respectively) and the EACH-Q (6.5% and 13%, respectively). Correlations were improved with the second set of self-report tests (range, .310-.595 to .414-.808).
Conclusions:
The fact that all self-report tools correlated better with a community-based measure of MWD using GPS than with laboratory results confirms that they measure what they aim to: community-based MWD. In addition, prescription of a community walk might help patients to better estimate their walking limitation.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease III: Interprofessional Care
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Artery Disease IV: Nursing Management

