Related Experiment Video
Updated: May 14, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Spinal screw penetration of the aorta
Harleen K Sandhu1, Kristofer M Charlton-Ouw, Ali Azizzadeh
1Department of Cardiothoracic and Vascular Surgery, University of Texas Medical School at Houston, Memorial Hermann Hospital-Heart and Vascular Institute, Houston, Tex 77030, USA.
Abstract:
Aortic injury is a complication of spinal instrumentation with treatment challenges, especially with hardware infection. We present two cases of spinal screws penetrating the descending thoracic aorta (DTA). Case 1 had pain after T6-T7 fusion with screw penetration of the DTA causing pseudoaneurysm. Case 2 had perforation of the DTA by a T4 screw with infected pseudoaneurysm. Neither was an endovascular candidate and both underwent open repair. Although endovascular approaches have benefits in aortic aneurysm repair, the techniques of open thoracic aortic repair remain relevant.