Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Relative Motion Analysis - Acceleration01:10

Relative Motion Analysis - Acceleration

A slider-crank mechanism converts rotational motion from the crank into linear motion of the slider or vice versa. This mechanism consists of three main parts: the crank, the connecting rod, and the slider. The movement of the slider-crank is an example of general plane motion as the fluctuating angle between the crank and the connecting rod. Consider a segment AB where point A is at the end of the slider and point B is on the diametrically opposite end to point A, on a crack. The variance in...
Structural Classification of Joints01:20

Structural Classification of Joints

Joints, also known as articulations, are classified based on their structural characteristics, i.e., based on whether the articulating surfaces of the adjacent bones are directly connected by fibrous connective tissue or cartilage, or whether the articulating surfaces contact each other within a fluid-filled joint cavity. These differences serve to divide the joints of the body into three structural classifications.
A fibrous joint is where the adjacent bones are united by fibrous connective...
Deformations in a Symmetric Member in Bending01:18

Deformations in a Symmetric Member in Bending

When analyzing the deformation of a symmetric prismatic member subjected to bending by equal and opposite couples, it becomes clear that as the member bends, the originally straight lines on its wider faces curve into circular arcs, with a constant radius centered at a point known as Point C. This phenomenon helps to understand the stress and strain distribution within the member more clearly.
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Deformation of Member under Multiple Loadings01:11

Deformation of Member under Multiple Loadings

When a rod is made of different materials or has various cross-sections, it must be divided into parts that meet the necessary conditions for determining the deformation. These parts are each characterized by their internal force, cross-sectional area, length, and modulus of elasticity. These parameters are then used to compute the deformation of the entire rod.
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Plastic Deformation in Circular Shafts01:20

Plastic Deformation in Circular Shafts

When materials are subjected to forces that surpass their yield strength, they undergo a process known as plastic deformation. This results in a permanent alteration or strain in their structure. This concept can be specifically applied to circular shafts, where the deformation leads to a change in its shape. The precise evaluation of this plastic deformation requires understanding the stress distribution within the circular shaft, which is achieved by calculating the maximum shearing stress in...
Plastic Deformations of Members with a Single Plane of Symmetry01:21

Plastic Deformations of Members with a Single Plane of Symmetry

When a structural member undergoes plastic deformation due to bending, it is crucial to understand the position of the neutral axis and the stress distribution. This member, characterized by a single plane of symmetry, exhibits a uniform stress distribution, with negative stress above the neutral axis and positive stress below. Notably, the neutral axis does not align with the centroid of the cross-section. This misalignment is typical in cases where the cross-section is not rectangular or...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A photon source model for alpha-emitter radionuclides.

Physics in medicine and biology·2024
Same author

Annihilation photon GAN source model for PET Monte Carlo simulation.

Physics in medicine and biology·2023
Same author

Analytical modeling and Monte Carlo simulations of multi-parallel slit and knife-edge slit prompt gamma cameras.

Physics in medicine and biology·2023
Same author

Tiny changes in tomographic system matrices can cause large changes in reconstruction quality.

Physics in medicine and biology·2022
Same author

Evaluation of the impact of a scanner prototype on proton CT and helium CT image quality and dose efficiency with Monte Carlo simulation.

Physics in medicine and biology·2022
Same author

Erratum: CCMod: a GATE module for Compton camera imaging simulation (2020<i>Phys. Med. Biol.</i><b>65</b>055004).

Physics in medicine and biology·2021
Same journal

Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

Physics in medicine and biology·2026
Same journal

Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

Physics in medicine and biology·2026
Same journal

Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

Physics in medicine and biology·2026
Same journal

Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

Physics in medicine and biology·2026
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: May 14, 2026

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping
09:41

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping

Published on: April 21, 2023

Registration of sliding objects using direction dependent B-splines decomposition.

V Delmon1, S Rit, R Pinho

  • 1CREATIS; CNRS UMR5220, Inserm U1044, INSA-Lyon; Université Lyon 1, Université de Lyon, Villeurbanne, France. Léon Bérard Cancer Center, University of Lyon, F-69373 Lyon, France. vivien.delmon@creatis.insa-lyon.fr

Physics in Medicine and Biology
|February 8, 2013
PubMed
Summary
This summary is machine-generated.

This study introduces a novel method for deformable image registration that effectively handles sliding motion in medical imaging. The new approach significantly reduces registration errors, improving accuracy for lung cancer patient scans.

More Related Videos

Quantification of Strain in a Porcine Model of Skin Expansion Using Multi-View Stereo and Isogeometric Kinematics
14:14

Quantification of Strain in a Porcine Model of Skin Expansion Using Multi-View Stereo and Isogeometric Kinematics

Published on: April 16, 2017

Related Experiment Videos

Last Updated: May 14, 2026

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping
09:41

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping

Published on: April 21, 2023

Quantification of Strain in a Porcine Model of Skin Expansion Using Multi-View Stereo and Isogeometric Kinematics
14:14

Quantification of Strain in a Porcine Model of Skin Expansion Using Multi-View Stereo and Isogeometric Kinematics

Published on: April 16, 2017

Area of Science:

  • Medical imaging
  • Computational anatomy
  • Image processing

Background:

  • Sliding motion in deformable image registration causes discontinuities, complicating accurate anatomical alignment.
  • Existing methods struggle to precisely model and correct for sliding motion, impacting registration reliability.

Purpose of the Study:

  • To develop and evaluate a novel deformable image registration method capable of handling sliding motion.
  • To improve the accuracy and robustness of image registration in the presence of complex tissue deformations.

Main Methods:

  • A new method utilizing multiple B-spline transforms to decompose deformation into sliding regions.
  • Discontinuities are allowed at region interfaces while enforcing interface matching to prevent unrealistic deformations.
  • The method was validated on 16 lung cancer patient datasets.

Main Results:

  • The proposed method achieved a significantly lower target registration error (TRE) of 1.5 mm compared to a single B-spline approach (3.7 mm).
  • Registration accuracy was comparable to a multi-B-spline approach without sliding constraints (1.4 mm TRE).
  • The method demonstrated 37% fewer gaps and overlaps along region interfaces compared to the unconstrained multi-B-spline method.

Conclusions:

  • The proposed multiple B-spline transform method effectively addresses sliding motion in deformable image registration.
  • This approach enhances registration accuracy and reduces artifacts, particularly in challenging anatomical regions.
  • The findings suggest improved clinical applicability for image-guided interventions and treatment planning.