A Piórek1, Z Adamiak, Y Zhalniarovich
1Department of Surgery and Radiology, Faculty of Veterinary Medicine, University of Warmia and Mazury, Oczapowskiego 14, 10-718 Olsztyn, Poland. piux@wp.pl
Abstract:
This paper presents the results of a study of the treatment of transverse tibial shaft fractures in six sheep with the use of interlocking nails and type I extemal fixators. During surgery, tibial osteotomy was performed to induce an experimental fracture which was stabilized using a type I extemal fixator. Osteosynthesis was monitored for nine weeks by performing clinical tests, observing the degree of lameness and subjecting the patients to weekly radiological examinations. After nine weeks, the animals were euthanized, and samples of bone callus were sampled for histopathological analyses. Weight bearing on the fractured limb began on day 2 to 4 after treatment. Limb function was fully restored around five weeks after surgery. Radiograms taken during the observation period revealed gradual hyperplasia and progressing mineralization of bone callus at different stages of healing. The histopathological picture of the bone callus was characteristic of the phase of bone turnover and remodeling.
More Related Videos
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016