Supercharge nerve transfer to enhance motor recovery: a laboratory study
Scott J Farber1, Simone W Glaus, Amy M Moore
1Division of Plastic and Reconstructive Surgery, Washington University School of Medicine, St. Louis, MO 63110, USA.
Purpose:
To investigate the ability of a supercharge end-to-side (SETS) nerve transfer to augment the effect of regenerating native axons in an incomplete rodent sciatic nerve injury model.
Methods:
Fifty-four Lewis rats were randomized to 3 groups. The first group was an incomplete recovery model (IRM) of the tibial nerve complemented with an SETS transfer from the peroneal nerve (SETS-IRM). The IRM consisted of tibial nerve transection and immediate repair using a 10-mm fresh tibial isograft to provide some, but incomplete, nerve recovery. The 2 control groups were IRM alone and SETS alone. Nerve histomorphometry, electron microscopy, retrograde labeling, and muscle force testing were performed.
Results:
Histomorphometry of the distal tibial nerve showed significantly increased myelinated axonal counts in the SETS-IRM group compared with the IRM and SETS groups at 5 and 8 weeks. Retrograde labeling at 8 weeks confirmed increased motoneuron counts in the SETS-IRM group. Functional recovery at 8 weeks showed a significant increase in muscle-specific force in the SETS-IRM group compared with the IRM group.
Conclusions:
An SETS transfer enhanced recovery from an incomplete nerve injury as determined by histomorphometry, motoneuron labeling within the spinal cord, and muscle force measurements.
Clinical Relevance:
An SETS distal nerve transfer may be useful in nerve injuries with incomplete regeneration such as proximal Sunderland II- or III-degree injuries, in which long regeneration distance yields prolonged time to muscle reinnervation and suboptimal functional recovery.