Risk of vascular access complications with frequent hemodialysis

Rita S Suri1, Brett Larive, Susan Sherer

  • 1Kidney Clinical Research Unit, University of Western Ontario, Room A2-346, Victoria Hospital, 800 Commissioners Road East, London, Ontario N6A 4G5, Canada. rita.suri@lhsc.on.ca

Frequent hemodialysis requires using the vascular access more often than with conventional hemodialysis, but whether this increases the risk for access-related complications is unknown. In two separate trials, we randomly assigned 245 patients to receive in-center daily hemodialysis (6 days per week) or conventional hemodialysis (3 days per week) and 87 patients to receive home nocturnal hemodialysis (6 nights per week) or conventional hemodialysis, for 12 months. The primary vascular access outcome was time to first access event (repair, loss, or access-related hospitalization). Secondary outcomes were time to all repairs and time to all losses. In the Daily Trial, 77 (31%) of 245 patients had a primary outcome event: 33 repairs and 15 losses in the daily group and 17 repairs, 11 losses, and 1 hospitalization in the conventional group. Overall, the risk for a first access event was 76% higher with daily hemodialysis than with conventional hemodialysis (hazard ratio [HR], 1.76; 95% confidence interval [CI], 1.11-2.79; P=0.017); among the 198 patients with an arteriovenous (AV) access at randomization, the risk was 90% higher with daily hemodialysis (HR, 1.90; 95% CI, 1.11-3.25; P=0.02). Daily hemodialysis patients had significantly more total AV access repairs than conventional hemodialysis patients (P=0.011), with 55% of all repairs involving thrombectomy or surgical revision. Losses of AV access did not differ between groups (P=0.58). We observed similar trends in the Nocturnal Trial, although the results were not statistically significant. In conclusion, frequent hemodialysis increases the risk of vascular access complications. The nature of the AV access repairs suggests that this risk likely results from increased hemodialysis frequency rather than heightened surveillance.

Related Concept Videos

Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this measurement...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...