Differences in automated and manual blood pressure measurement in hospitalized psychiatric patients
Lucy Neinguii Suokhrie1, Carole-Rae Reed, Carolyn Emory
1Cooper University Hospital, Camden, NJ, USA. Suokhrie-lucy@cooperhealth.edu
Abstract:
Few studies have been conducted recently with noncritically ill patients evaluating commonly used automated blood pressure (BP) devices. The purpose of this study was to compare BP values obtained using a manual sphygmomanometer versus an oscillometric automated electronic BP device on an acute care psychiatry unit. A method-comparison design was used, and data were analyzed using the Bland-Altman method. Outliers were removed, resulting in 39 participants for analyses of systolic readings and 41 participants for diastolic readings. Paired t tests revealed a significant difference in manual versus automatic systolic BP readings (p < 0.05). Automated readings averaged 3.9 points higher. No significant differences in diastolic readings (p = 0.72) were found. Care must be taken in using automated or manual BP readings to make important clinical decisions. Based on these findings, a protocol was instituted in an acute care psychiatry unit indicating that BP must be measured manually for patients with medication-hold parameters for BP.
More Related Videos
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: