Related Experiment Video
Updated: May 14, 2026

The Measurement and Treatment of Suppression in Amblyopia
Published on: December 14, 2012
Rebound tonometry in children: a report by the American Academy of Ophthalmology
Scott R Lambert1, Michele Melia, Angela N Buffenn
1R. Howard Dobbs Professor, Departments of Ophthalmology and Pediatrics, Emory University, Atlanta, Georgia, USA.
Insights
Rebound tonometry offers a feasible method for measuring intraocular pressure (IOP) in children, though readings may differ from applanation tonometry. This technique allows IOP measurement without general anesthesia in many pediatric cases.
Area of Science:
- Ophthalmology
- Pediatric Ophthalmology
- Tonometry
Background:
- Accurate intraocular pressure (IOP) measurement is crucial for diagnosing and managing pediatric glaucoma.
- Traditional applanation tonometry can be challenging in young children, often requiring sedation or general anesthesia.
- Rebound tonometry presents a potential alternative for IOP assessment in pediatric populations.
Purpose of the Study:
- To compare intraocular pressure (IOP) measurements obtained by rebound tonometry and applanation tonometry in children.
- To evaluate the feasibility of using rebound tonometry and applanation tonometry in pediatric patients.
- To assess the accuracy and reliability of rebound tonometry in pediatric IOP assessment.
Main Methods:
- A systematic literature search of PubMed and Cochrane Library databases was conducted (last search June 2012).
- Four studies met the inclusion criteria after full-text review, with evidence levels assigned.
- Data from level II and level III studies were analyzed to compare IOP measurements and assess feasibility.
Main Results:
- No level I evidence was found; 2 level II and 2 level III studies were included.
- Rebound tonometry yielded IOP readings 2-3 mmHg higher than Goldmann applanation tonometry in most studies.
- Bland-Altman analysis indicated that IOP differences increased with higher IOP values.
- Rebound tonometry demonstrated a higher success rate for IOP measurement in children aged 3 years and younger compared to noncontact tonometry.
Conclusions:
- Rebound tonometry appears to be a reasonably accurate device for measuring IOP in children.
- This method facilitates IOP measurement in many pediatric cases without the need for general anesthesia.
- Further research is needed to better understand how IOP measurement differences vary across different instruments and IOP levels.
Objective:
To compare intraocular pressure (IOP) measurements in children 18 years of age and younger using rebound tonometry and applanation tonometry and the feasibility of using these techniques in children.
Methods:
Literature searches of the PubMed and the Cochrane Library databases were last conducted in June 2012 and resulted in 43 citations, including citations not in English. Of these 43 citations, 4 studies met the inclusion criterion following full text review. A level of evidence rating was assigned to each study using criteria specifically developed for this assessment.
Results:
No level I study was found in the literature search, and 2 level II and 2 level III studies were identified. Intraocular pressure was 2 to 3 mmHg higher using rebound tonometry compared with Goldmann applanation tonometry in the 2 level II studies performed in a clinic setting and in 1 level III study performed on children under general anesthesia. However, IOP was lower in 1 level III study in which noncontact applanation tonometry was compared with rebound tonometry. Bland-Altman plots showed that the difference in IOP for rebound versus Goldmann applanation tonometry increased as the IOP increased. The success rate for measuring IOP was markedly higher in children 3 years of age and younger using rebound tonometry compared with noncontact tonometry in 1 level III study.
Conclusions:
Rebound tonometry seems to be a reasonably accurate instrument that allows the IOP to be measured in many children without using general anesthesia. More data are required to assess better how the differences between instruments vary with IOP measurement.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Angle Closure Glaucoma: Treatment