Related Experiment Video
Updated: May 14, 2026

Ultrasonography of the Adult Male Urinary Tract for Urinary Functional Testing
Published on: August 14, 2019
Impact of the endorectal ultrasound probe on uroflow parameters in males
F M Solivetti1, G Coscarella, G Dirozzi
1Department of Radiology, The Dermosyphilopathic Hospital of St. Maria and St. Gallicano, Istituti Fisioterapici Ospitalieri (IFO), Rome, Italy.
Objectives:
The aim of this study was to test the null hypothesis that the presence in the rectum of an endorectal ultrasound probe during transrectal voiding ultrasonography (TRVUS) would have no significant effect on uroflowmetry parameters.
Patients And Methods:
We studied 43 randomly selected men undergoing TRVUS of the prostate for non-neurogenic lower urinary tract symptoms. Uroflowmetry was performed immediately before and during the TRVUS. Results were compared with a paired Student's t test; the null hypothesis was confirmed by p values >0.05.
Results:
Forty patients were able to void with the endorectal probe inserted, and 95% described this micturition as representative of their usual voiding behavior. No significant statistical difference was found between uroflowmetry parameters before and during TRVUS, confirming our null hypothesis.
Conclusion:
Our data suggest that uroflowmetry in combination with TRVUS can be a reliable tool for evaluating disorders of micturition in males, at least in selected cases.
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Imaging Studies II: Ultrasonography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies VI: Voiding Cystourethrography and Cystography
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies IV: Magnetic Resonance Imaging