Related Experiment Video
Updated: May 14, 2026

Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
CdTe quantum dots enhance feasibility of EvaGreen-based real-time PCR with decent amplification fidelity
Fuming Sang1, Zhizhou Zhang, Zhong Xu
1School of Marine Science and Technology, Harbin Institute of Technology, Weihai 264209, People's Republic of China.
Abstract:
Quantitative real-time PCR (qPCR), as an important quantitative technique for nucleic acids, has been widely used in many fields including clinical diagnosis, molecular biology, and cancer research. However, non-specific amplification products are still a frequent problem in qPCR. In this study, we investigated the effects of QDs on real-time amplification based on either SYBR Green I or EvaGreen. It was found that QDs could raise the amplification sensitivity and thus enhance the efficiency using SYBR Green I detection system. In the case of EvaGreen detection systems, addition of QDs also led to a better correlation coefficient than without QDs. EvaGreen-based system gave sharper peaks for melting curves than SYBR Green I. The experiments indicated that the polymerase activity could be partially blocked by QDs at the pre-PCR temperatures, resulting in the improvement of PCR specificity. These results indicated that CdTe QDs could be used as a descent qPCR enhancer. Good amplification fidelity in QDs-facilitated qPCR was also a plus that has not been reported elsewhere.